Antimony Pentachloride Chemical Storage Specifications

Compliant storage and rental solutions for Antimony Pentachloride (SbCl5). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Flammable hazardFlammable Storage

Chemical formula

Antimony Pentachloride molecular formula

About Antimony Pentachloride

Antimony pentachloride is a yellowish or colorless fuming liquid with a pungent odor. It is used as a reagent in chemical synthesis and is also used in the production of other antimony compounds.

Structured hazard data

Hazard class
8
Storage category
Flammable Storage
Flammable
Yes
Flash point
N/A
Storage temperature
-4°F to 122°F
Recommended extinguishing agent
Dry Chemical
Compatibility / segregation
Strong oxidizing agents.

Corrosive

Fire Suppression System

Dry Chemical fire suppression is recommended for Antimony Pentachloride

  • Water

    Water

  • Dry Chemical

    Dry Chemical · Recommended

  • CO₂ / Other

    CO₂ / Other

Guidance: Dry Chemical fire suppression is generally recommended for Antimony pentachloride (SbCl5). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Additional extinguishing notes: Dry Chem Powder

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Antimony pentachloride should account for its listed hazards (8), climate control needs (-4°F to 122°F), and segregation requirements. Strong oxidizing agents.

Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.

Properties: Boiling point: 140°C, Melting point: -49°C, Density: 2.34 g/cm³, Soluble in water and decomposes in alcohol.

Matched to this chemical

Recommended storage solutions for Antimony Pentachloride

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    • 228 Square Feet storage
    View product
  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 10 ft
    • 12 Barrels
    • 55 Gal Storage Drums
    • 48 Square Feet storage
    View product
  • Fire-rated4 hourChemical Tote Storage

    Single Tote & Pallet Storage

    • 4-Hour Fire-Rated 6' Deep 1-Tote-Deep
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Antimony pentachloride be stored?

Store Antimony pentachloride in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (8). Climate range guidance: -4°F to 122°F. Compatibility notes: Strong oxidizing agents. US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Antimony pentachloride flammable?

Yes — Antimony pentachloride is flagged as a flammable hazard in this database (Yes). Flash point: N/A. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.

What hazard class is Antimony pentachloride?

Antimony pentachloride is listed as: 8. Corrosive

What fire suppression is recommended for Antimony pentachloride?

Dry Chemical fire suppression is generally recommended for Antimony pentachloride (SbCl5). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Antimony pentachloride storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Antimony pentachloride. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.